Cell cytotoxicity assays
By Harbell, J.W. - Koontz, S.W. - Lewis, R.W. - Lovell, D. - Acosta, D.
| Record number: | 2752212 |
|---|---|
| Category: | animal use alternatives - assays - irritant properties - eyes - cytotoxicity - cell lines - dyes - fibroblasts - surfactants - chemical substances |
Twenty-seven data sets from 12 cellular cytotoxicity assays, intended to predict ocular irritation, were submitted to the Interagency Regulatory Alternatives Group (IRAG) for review. These data consisted of paired in vivo (Draize) and in vitro responses to individual chemicals and formulations. In vivo data consisted of individual tissue scores so that the predictive value of the in vitro assay could be assessed for each tissue response normally measured in the standard Draize assay. Data were compiled and evaluated according to the IRAG Guideline Document. The Pearson's linear correlation coefficient was used as the first step in assessing the relationship between the in vitro and in vivo responses. The majority of the data sets represented the study of surfactant-based materials. In many cases, there was good correlation between the in vitro scores and the in vivo tissue responses. Most pronounced were the particularly good correlations between the in vitro scores and conjunctival redness scores across most of the assays. Based on the data submitted, a number of the cell cytotoxicity assays show considerable promise as screens for ocular irritancy. None of the submitters recommended that their cell cytotoxicity assay be used as a sole replacement for in vivo assessment. For almost all of these assays, the materials being tested should be water-soluble/miscible. The toxicity of products with reserve acidity or alkalinity or with high reactivity may be underestimated. A given user may prefer certain assays depending on the types of materials to be tested, the expected range of toxicities and the resources available. The cell cytotoxicity assays can serve as a valuable component of a tiered or battery testing program. As with any assay, a sufficient number of replicate values, concurrent positive and negative controls, and a strict adherence to assay acceptance criteria are essential to produce credible data.
Issued: Jan 1997
Journal Title: Food and chemical toxicology
ISSN: 0278-6915
Volume issue: 35 v. 1 no.
Pages: 79 - 126
Notes:
Paper presented at the Workshop on Eye Irritation Testing: Practical Applications of Non-Whole Animal Alternatives held November 14-19, 1993, Baltimore, Maryland.
AGRICOLA identifier: IND20608741
Thanks for your feedback! Please note that we cannot reply to you unless you send us an email.
What are you looking for?
We value your feedback so we can improve the information on the page. Please add your email address if you would like a reply. Thank you in advance for your help.!
Please contact us by email if you have any questions.