A study of UV filter chemicals from annex VII of European Union Directive 76/768/EEC, in the in vitro 3T3 NRU phototoxicity test

By Spielmann, H. - Balls, M. - Dupuis, J. - Pape, W.J.W. - Silva, O. de. - Holzhutter, H.G. - Gerberick, F. - Liebsch, M. - Lovell, W.W. - Pfannenbecker, U.

In 1996, the Scientific Committee on Cosmetology of DGXXIV of the European Commission asked the European Centre for the Validation of Alternative Methods to test eight UV filter chemicals from the 1995 edition of Annex VII of Directive 76/768/EEC in a blind trial in the in vitro 3T3 cell neutral red uptake phototoxicity (3T3 NRU PT) test, which had been scientifically validated between 1992 and 1996. Since all the UV filter chemicals on the positive list of EU Directive 76/768/EEC have been shown not to be phototoxic in vivo in humans under use conditions, only negative effects would be expected in the 3T3 NRU PT test. To balance the number of positive and negative chemicals, ten phototoxic and ten non-phototoxic chemicals were tested under blind conditions in four laboratories. Moreover, to assess the optimum concentration range for testing, information was provided on appropriate solvents and on the solubility of the coded chemicals. In this study, the phototoxic potential of test chemicals was evaluated in a prediction model in which either the Photoirritation Factor (PIF) or the Mean Photo Effect (MPE) were determined. The results obtained with both PIF and MPE were highly reproducible in the four laboratories, and the correlation between in vitro and in vito data was almost perfect. All the phototoxic test chemicals provided a positive result at concentrations of 1 microgram/ml, while nine of the ten non-phototoxic chemicals gave clear negative results, even at the highest test concentrations. One of the UV filter chemicals gave positive results in three of the four laboratories only at concentrations greater than 100 microgram/ml, the other laboratory correctly identified all 20 of the test chemicals. An analysis of the impact that exposure concentrations had on the performance of the test revealed that the optimum concentration range in the 3T3 NRU PT test for determining the phototoxic potential of chemicals is between 0.1 microgram/ml and 10 microgram/ml, and that false positive results can be obtained at concentrations greater than 100 microgram/ml. Therefore, the positive results obtained with some of the UV filter chemicals only at concentrations greater than 100 microgram/ml do not indicate a phototoxic potential in vivo. When this information was taken into account during calculation of the overall predictivity of the 3T3 NRU PT test in the present study, an almost perfect correlation of in vitro versus in vivo results was obtained between (95% and 100%), when either PIF or MPE were used to predict the phototoxic potential. The management team and participants therefore conclude that the 3T3 NRU PT test is a valid test for correctly assessing the phototoxic potential of UV filter chemicals, if the defined concentration limits are taken into account.



Issued: Sept/Oct 1998

Journal Title: Alternatives to laboratory animals

ISSN: 0261-1929

Volume issue: 26 v. 5 no.

Pages: 679 - 7008

AGRICOLA identifier: IND21989825
This page was updated on 11 February 2021
Did you find what you were looking for?
Yes, I found it! No, I did not!

Thanks for your feedback! Please note that we cannot reply to you unless you send us an email.

What are you looking for?

We value your feedback so we can improve the information on the page. Please add your email address if you would like a reply. Thank you in advance for your help.!

Please contact us by email if you have any questions.

Thanks for your feedback! Please note that we cannot reply to you unless you send us an email.

RadioButtonList field
 

Abonnér på nyhetsbrevene fra Norecopa