Evaluation of a rule base for identifying contact allergens by using a regulatory database: comparison of data on chemicals notified in the European Union with "structural alerts" used in the DEREK expert system
By Zinke, S. - Gerner, I. - Schlede, E.
| Record number: | 2928545 |
|---|---|
| Category: | animal use alternatives - allergens - structure-activity relationships - molecular conformation - skin - databases - prediction - toxicology - expert systems - drugs - veterinary drugs - animal use reduction |
To assess the suitability of the use of structural alerts to identify the skin-sensitising properties of chemicals, the 40 originally published structural alerts for the prediction of skin-sensitisation properties used by the DEREK system (which now contains 59 structural alerts), have been evaluated against a database developed in the German Federal Institute for Health Protection of Consumers and Veterinary Medicine (BgVV), which contains data submitted under the procedure for notifying new chemicals within the European Union. The evaluation of the 40 structural alerts used in DEREK revealed that eight of the 40 structural alerts for the prediction of skin-sensitising potential could be used without any further refinement. Ten structural alerts may need further specifications or refinements in order avoid false-positive predictions--proposals for refinement are discussed. Not enough substances were found within the BgVV database (containing data for more than 1000 substances) to evaluate ten of the DEREK substructures; hence, for these structural alerts, a judgement on their suitability for prediction of skin-sensitisation properties in expert systems is not possible. For 12 structural alerts, no comparative result could be obtained, because these rules did not "fire" for any of the examined chemicals. As a general result of the evaluation process, the approach of using structural alerts for the prediction of skin-sensitising properties of chemicals proved to be reliable. Proposals are given for a refinement of the structural alerts for prediction of contact allergy used in the DEREK system. In addition, advice and several preconditions are given, that apply when trying to teach a computer system to use structural alerts to predict toxicological properties.
Issued: May/June 2002
Journal Title: Alternatives to laboratory animals
ISSN: 0261-1929
Volume issue: 30 v. 3 no.
Pages: 285 - 298
AGRICOLA identifier: IND23336520
Thanks for your feedback! Please note that we cannot reply to you unless you send us an email.