Evaluation and prevalidation of an immunotoxicity test based on human whole-blood cytokine release
By Langezaal, I. - Hoffmann, S. - Hartung, T. - Coecke, S.
| Record number: | 2928552 |
|---|---|
| Category: | animal use replacement - blood - humans - immunotoxicity - immunostimulants - immunosuppressive agents - interleukin-1 - interleukin-4 - lymphocytes - monocytes - in vitro studies - immunosuppression (physiological) - immune response - in vivo studies - lethal dose 50 - dose response - screening |
Immunotoxicology is a relatively new field in toxicology, and is one of emerging importance, because immunotoxicity appears to contribute to the development of cancer, autoimmune disorders, allergies and other diseases. At present, there is a lack of human cell-based immunotoxicity assays for predicting the toxicity of xenobiotics toward the immune system in a simple, fast, economical and reliable way. Existing immunotoxicity tests are mainly performed in animals, although species differences favour human-based testing. Whole-blood cytokine release models have attracted increasing interest, and are broadly used for pharmacological in vitro and ex vivo studies, as well as for pyrogenicity testing. We have adapted those methods for immunotoxicity testing, to permit the potency testing of immunostimulants and immunosuppressants. Following stimulation with a lipopolysaccharide or staphylococcal enterotoxin B, monocytes and lymphocytes release interleukin-1beta and interleukin-4, respectively. Thirty-one pharmaceutical compounds, with known effects on the immune system, were used to optimise and standardise the method, by analysing their effects on cytokine release. The in vitro results were expressed as IC50 values for immunosuppression, and SC4 (fourfold increase) values for immunostimulation, and compared with therapeutic serum concentrations of the compounds in patients, and in vivo LD50 values from animal studies. The in vitro results correlated well with the in vivo data, so the test appears to reflect immunomodulation. Results were reproducible (CV = 20 +/- 5%), and the method could be transferred to another laboratory (r2 = 0.99). We therefore propose this method for further validation and for use in immunotoxicity testing strategies.
Issued: /Dec 2002
Journal Title: Alternatives to laboratory animals
ISSN: 0261-1929
Volume issue: 30 v. 6 no.
Pages: 581 - 595
AGRICOLA identifier: IND23337750
Thanks for your feedback! Please note that we cannot reply to you unless you send us an email.
What are you looking for?
We value your feedback so we can improve the information on the page. Please add your email address if you would like a reply. Thank you in advance for your help.!
Please contact us by email if you have any questions.