Echocardiography, color-coded doppler imaging, and abdominal sonography, a non-invasive method for investigation of heart and aortic morphology and function in female gottingen minipigs: method and reference values for M-mode, B-mode and flow parameters
By Konrad, D. - Weber, K. - Corney, S. - Allen, T.R. - Terrier, C.
| Record number: | 4214515 |
|---|---|
| Category: | miniature swine - laboratory animals - blood flow - cardiac output - arteries - body weight - laboratory equipment - animal welfare - heart rate - ultrasonography - echocardiography - animal use refinement |
Objective: The aim of the study reported here was to set up a method for echocardiography (EC) and abdominal sonography and to obtain EC reference values for left ventricular (LV) morphology and function and sonographic abdominal aortic morphology, function, and flow values in conscious, unsedated Gottingen minipigs. Methods: Applying a standardized investigation procedure, the following parameters were measured by use of M-mode EC, color-coded Doppler imaging, and B-mode sonography, or were calculated, in 58 female minipigs: LV end-diastolic and end-systolic diameter, interventricular septum thickness, LV caudal wall thickness, LV end-diastolic volume and end-systolic volume, fractional shortening, ejection fraction, and percentage of thickening of interventricular septum and LV caudal wall. In addition, morphology, pulsatility, flow values, and flow patterns in the abdominal aorta were recorded or calculated during abdominal sonography and color-coded Doppler imaging. Results: Variable EC values were obtained due to individual variations of motor activity. Variation could be reduced by accustoming the animals to a standardized investigation procedure. Reference values could be obtained for EC, partially indicating clear correlation with body weight. Color-coded Doppler and Doppler spectra did not indicate flow disturbances in large arterial abdominal vessels. Conclusions: Results indicate that handling during EC and sonography can cause discomfort in unsedated minipigs that may interfere with recording of valid reference values for functional cardiac parameters in young animals. Accustoming the animals to a standardized investigation procedure reduces stress to a satisfactory level and enables data recording. Thus the minipig is considered suitable for assessment of cardiovascular parameters in experimental or toxicologic studies.
Issued: Aug 2000
Journal Title: Comparative medicine
ISSN: 1532-0820
Volume issue: 50 v. 4 no.
Pages: 405 - 409
AGRICOLA identifier: IND22792717
Thanks for your feedback! Please note that we cannot reply to you unless you send us an email.
What are you looking for?
We value your feedback so we can improve the information on the page. Please add your email address if you would like a reply. Thank you in advance for your help.!
Please contact us by email if you have any questions.