Study of corneal lesions induced by 1,318-nm laser radiation pulses in Dutch Belted rabbits (Oryctolagus cuniculus). [Erratum: 2003 June, v. 53, no. 3, p. 313.]
By Ketzenberger, B. - Johnson, T.E. - Van Gessel, Y.A. - Wild, S.P. - Roach, W.P.
| Record number: | 3019316 |
|---|---|
| Category: | rabbits - cornea - lasers - dosage - infrared radiation - animal use alternatives - occupational health and safety - animal use reduction - wavelengths |
Background and Purpose: Use of high-energy near-infrared lasers is becoming more prevalent in todayʾs industries, such as technology, medicine, and military operations. Despite wide-range use of these lasers, threshold, median effective dose (ED50), and the mechanism of laser-tissue interaction are not well defined at the 1,318-nm wavelength for human corneal exposures. The goals of the study reported here were to establish the ED50 for single-pulse, 1,318- nm laser exposures on the Dutch Belted rabbit cornea and to characterize microscopic changes. Results of this study were then compared with those of previous corneal studies. Methods: A neodymium:yttrium aluminum garnet (Nd:YAG) laser was used to deliver single 1,318-nm wavelength pulses to the corneas of 10 female Dutch Belted rabbits (Oryctolagus cuniculus). Single pulses of 0.5-ms duration and radiant energy ranging from 116 to 2,250 J/cm2 irradiated the exposure sites. Sites were clinically evaluated for presence of a lesion at one hour and 24-h after exposure. Results of the 24-h evaluation were used to determine the (ED50). Corneas were subsequently collected at the 24-h endpoint for microscopic evaluation. Results: The ED50 for 1,318-nm exposures to the rabbit cornea was determined to be 382 J/cm2, as measured at the 1/e2 (0.865 times that of the peak power per unit area). At each exposure site, there was a small (< 1 mm in diameter), white, circular, well demarcated corneal lesion characterized histologically by a band of stromal coagulative necrosis and endothelial necrosis, with sparing of the anterior epithelium. In addition, there appeared some potential for damage to Descemetʾs membrane at the highest energy level tested. Conclusions: Findings indicate that the rabbit cornea is subject to injury at the 1,318-nm wavelength with the established ED50.
Issued: Dec 2002
Journal Title: Comparative medicine
ISSN: 1532-0820
Volume issue: 52 v. 6 no.
Pages: 513 - 517
AGRICOLA identifier: IND23315773
Takk for din tilbakemelding! Vær oppmerksom på at vi ikke kan kontakte deg hvis ikke du oppgir din epostadresse.
Hva lette du etter?
Gi oss gjerne en tilbakemelding slik at vi kan forbedre informasjonen på siden. På forhånd takk for hjelpen! Vennligst skriv inn din epostadresse hvis du vil ha et svar.
Kontakt oss gjerne på e-post hvis du har spørsmål.