Correlation between ToBI test and in vivo titration for diphtheria and tetanus
By Wagner Quintilio - Josana Kapronezai - Fábio Alessandro de Freitas
| Record number: | 5537744 |
|---|---|
| Category: | animal use alternatives - blood serum - horses - humans - immune response - in vivo studies - quality control - tetanus - titration - vaccines |
Alternatives to animal testing for quality control of biologicals have been a goal since 1959. Instituto Butantan has been developing such methods for quality control of biologicals for human use (vaccines and hyperimmune equine sera) for the last 13 years. In this paper we compare the modified ToBI test and the in vivo seroneutralization test to assess immunogenicity of diphtheria and tetanus vaccines and hyperimmune sera. Data from the last 10 years were statistically analyzed to compare the results for in vivo and in vitro titrations (diphtheria, n = 525 and tetanus, n = 455). The agreement between the tests depended on the serum titer range. For both diphtheria and tetanus components, the correlation and concordance coefficient was higher as the serum titer increased. Overall, the in vitro/in vivo titer ratio did not vary systematically over the range of measurements. These results indicate that although the in vitro ToBI test is not completely able to replace the in vivo serum titration, it is a useful tool to guide the tests during the production process, which can reduce the number of animals used for lot release.
Issued: January 2015
Journal Title: Biologicals
ISSN: 1045-1056
Volume issue: 43 v.
Pages: 55 - 61
Publisher: Elsevier Ltd
AGRICOLA identifier: IND605537744
DOI identifier: 10.1016/j.biologicals.2014.10.001
Takk for din tilbakemelding! Vær oppmerksom på at vi ikke kan kontakte deg hvis ikke du oppgir din epostadresse.
Hva lette du etter?
Gi oss gjerne en tilbakemelding slik at vi kan forbedre informasjonen på siden. På forhånd takk for hjelpen! Vennligst skriv inn din epostadresse hvis du vil ha et svar.
Kontakt oss gjerne på e-post hvis du har spørsmål.